ROCOZYER- Intelligent physical therapy massage robotic platform
Technology frees hands, Intelligence comfort life
- AI Robot Massage + radio frequency double-head design;
- 6-joint electric drive and AI image body recognition for precise and flexible movements;
- Integrated machine vision systems for real-time 3D imaging and accurate limb recognition;
- Intuitive 3D solid modeling and multi-angle visual observation;
- Subdivision processing of body parts, precise control, and dual massage modes;
Flexible collaborative robotic arm is based on 6-joint electric drive, and Al image body recognition, pre-programmed movement trajectory, more flexible and precise movement, higher collision avoidance, safety and reliability.
Machine’s vision systems are capable of recognizing limbs and subjects with high accuracy by processing 3D camera imagesin real time. Such system utilize advanced algorithms and techniques to accurately recognize human poses and movements, providing accurate guidance and control of flexible collaborative robotic arm.
3D solid modeling, multi-angle visual observation; real-time environment monitoring, convenient and intuitive; the machine’s own top view angle, can be safe self-testing.
Subdivision processing of body parts, accurate target parts, synchronous output. Precise control and intensity parameter adjustment, detection stroke setting accurate to millimeters, force perception accurate to 0.1N, more secure and controllable. Dual massage mode: single point pressing + path massage.
Standardised pre-set exclusive paths by part; customised paths for intelligently designated areas.
New single-point focus operation in the dynamicpath, with optional density and movement, isfully user-friendly and enhances comfort and target site effect.
New strength sensor on the treatment tip
Real-time close to the human body, perfect integration according to the body parts and situation, real-time dynamic adijustment of the strength, to meet the exclusive needs of each experiencer.
Massage + Radio Freauency Double-head Design
In-depth physical therapy rehabilitation: relieveocal pain after exercise and labor, relax muscles promote blood circulation, lactic acid and body metabolism, and accelerate the recovery of damaged tissues.
Superficialsubcutaneous treatment: eliminateexcess edema and fat, tighten body skin, anti-aging and body shaping.
Parameters
Robotic Arm | 6-joint electric drive |
Working Radius | ≤0.92m |
Standard Load Capacity | ≥5KG when towing, down pressure≥7KG |
Limit Load Capacity | ≥7KG when towing, down pressure≥8KG |
Force Acquisition Range | ≤+10KG, Resolution<0.1KG |
Single Track Length | 25000 nodes, more than 3 min |
Running Speed | ≤0.5m/s |
Control System | X86 fully enclosed embedded computer as the core, supplemented by Gigabit network port directly connected to the arm body controller, ultra-high integration |
Camera Sensor | A 2-in-1 highly integrated solution that combines live view camera + ToF deep view camera |
Tip Type | Single polar; multi polar |
RF Frequency | 470kHz |
Mainframe Size | 1000*500*1300mm |
Tip Size | Diameter 10.5cm; 7.8cm |
RF Power | 200W |
Net Weight | 130KG |